Product Details

The Optima TLX Ultracentrifuge features maximum performance capabilities of 657,000 x g and sample volumes ranging from 0.2 mL to 5.1 mL per tube.  The system features include imbalance-tolerant, direct vacuum-encased, and air-cooled drives.  It also has a rotor imbalance detection, moisture-purging vacuum pump, fixed angle rotors with a fluid-containment annulus, and programmability with up to five step changes.  It has ten selectable acceleration to deceleration rates and a microprocessor control.  It is an ultracentrifuge for maximum performance and convenience.

Additional features include:

  • Reduced separation time
  • Improved resolution
  • Greater volume Improves work flow and productivity
  • Reduces time spent transporting samples
  • Occupies less space
  • Chlorofluorocarbon-free, solid-state temperature control systems
  • Automatic rotor identification
  • User diagnostics

Specifications:

  • Height: 53.3 cm (21 in)
  • Width: 73.7 cm (29 in)
  • Depth: 58.4 cm (23 in)
  • Weight: 81 kg (178 lb)
  • Approximate Acceleration Time: 10 acceleration profiles--9 slow rates from 0 to 5,000 rpm followed by full acceleration to set speed; or maximum acceleration
  • Approximate Deceleration Time: 11 deceleration profiles--10 slow rates from 5,000 to 0 rpm, including coasting to a stop without brake; or full dynamic braking from set speed
  • Electrical Requirements: 60 Hz, 110 VAC, 12 A
  • Maximum Heat Dissipation into Room under Steady-State Conditions: 0.5 kW (1,750 Btu/hr)
  • Noise Level 1 Meter in Front of Centrifuge: < 60 dBA
  • Set Speed: Actual rotor speed ± 50 rpm of set speed
  • Set Temperature: 2 to 40°C in 0.1° increments
  • Set Time: to 99 hr 59 min
  • Speed Range: 5,000 to 120,000 rpm
  • Temperature Control: ± 2°C of set temperature (after equilibration)
  • Ambient Temperature Range: 15 to 35°C ambient
  • Clearances Required: 7.6 cm (3.0 in) both sides and rear
  • Humidity Restrictions: < 95% (noncondensing)
  • Pollution Degree: 2
  • Time -- Actual Display: Indicates run time remaining
  • Finish: Control panel: coated polycarbonate.
  • Top surface: urethane paint; other surfaces: general purpose paint.

The ALT Difference

  • Quality Used Lab Equipment
    All Items Tested to
    Manufacturer Spec
  • Used Microscopes For Sale
    More Than 12,000
    Items in Stock
  • Lab Equipment Warranty
    Up to 1-Year
    Warranty
  • Affordable Used Laboratory Equipment
    Price Match
    Guarantee
  • Discount Used Lab Equipment
    50%–80%
    off Retail

Join Our Mailing List

  • This field is for validation purposes and should be left unchanged.