Binder Series KBWF 240 - Growth Chamber
Designation | Series KMF |
Series feature | Constant climate chambers with expanded temperature / humidity range |
Important characteristics | * Temperature range: -10 °C to 100 °C * Humidity range: 10 % RH to 98 % RH * APT.line™ preheating chamber technology * Humidity regulation with capacitive humidity sensor and vapor humidification * Inner chamber made of stainless steel * BINDER APT-COM™ 3 Basic Edition communication software * Intuitive touchscreen controller with time-segment and real-time programming with internal data recording * Tight-sealing inner door made of safety glass (ESG) with special TIMELESS coating * 1 stainless steel rack * Access port with silicone plug, 30 mm, left * Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm * Computer interface: Ethernet * Door heating |
Features | * Temperature range: -10 °C to 100 °C * Humidity range: 10 % to 98 % RH * Humidity regulation with capacitive humidity sensor and vapor humidification * Inner chamber made of stainless steel * Intuitive touchscreen controller with time-segment and real-time programming with internal data recording |
Text of Series | The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant climate chamber is its low space requirement and flexibility in terms of water supply. The wide temperature and humidity range make this constant climate chamber ideally suited for stress testing series. |
TECHNICAL DATA
Description | KBWF240-230V * |
Article Number | 9020-0336 |
Performance Data Temperature | |
Temperature range with 100% illumination [°C] | 10…60 |
Temperature range without illumination cassettes [°C] | 0…70 |
Performance Data Climate | |
Temperature range with 100% illumination [°C] | 10…60 |
Temperature range without illumination cassettes [°C] | 10…70 |
Humidity range with illumination cassettes, with illumination [% RH] | 10…75 |
Humidity range without illumination [% RH] | 10…80 |
Lightdata per Illumination Cassettes | |
Daylight tubes [W/m²]* ** | 24 |
Daylight tubes [lx]* ** | 9000 |
Fluora® growth lamps [W/m²]* ** | 23 |
Fluora® growth lamps [lx]* ** | 7500 |
Arabidopsis lamps [W/m²]* ** | 32 |
Arabidopsis lamps [lx]* ** | 11000 |
Electrical data | |
Rated Voltage [V] | 200…240 |
Power frequency [Hz] | 50 |
Nominal power [kW] | 2.4 |
Unit fuse [A] | 16 |
Phase (Nominal voltage) [ph] | 1 |
Measures - Outer dimensions | |
Width net [mm] | 925 |
Height net [mm] | 1465 |
Depth net [mm] | 800 |
Wall clearance back [mm] | 100 |
Wall clearance sidewise [mm] | 100 |
Measures - Doors | |
Inner doors | 1 |
Unit doors | 1 |
Measures - Internal Dimensions | |
Width [mm] | 650 |
Height [mm] | 785 |
Depth [mm] | 485 |
Measures | |
Interior volume [L] | 247 |
Net weight of the unit (empty) [kg] | 214 |
permitted load [kg] | 100 |
Load per rack [kg] | 30 |
Environment-specific data | |
Energy consumption at 37 °C and 75 % RH [Wh/h] | 760 |
Sound-pressure level [dB(A)] | 53 |
Fixtures | |
Number of shelves (std./max.) | 2/7 |
Number of illumination cassettes (std./max.) | 2/2 |
* All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
** Average value, measured at 25 °C with a spherical sensor (±10 %) by 12 cm below the light cassette. The values given in W/m2 refer to global radiation.