Lab Equipment Sale

Category: HPLC Systems - Agilent | Subcategory: 1100 Systems

Agilent 1100 HPLC System including G1379A Degasser, G1312A Binary Pump, G1329A Autosampler, G1316A ColCom And G1315B DAD

Agilent 1100 HPLC System including G1379A Degasser, G1312A Binary Pump, G1329A Autosampler, G1316A ColCom And G1315B DAD Image

ITEM: 32573 In Stock

  • Free 90 Day Warranty
  • One Year Upgrade Available
  • Tested & Serviced Prior to Shipping

Or call (860) 691-2213

View the complete line of Refurbished Agilent 1100, 1200, 1260, 1290 HPLC Systems.

This Agilent 1100 HPLC System includes:

G1379A Degasser
G1312A Binary Pump 
G1329A Autosampler 
G1316A Column Compartment
G1315B Diode Array Detector
Solvent Tray
Computer Pre-Loaded with Chemstation Software
All required cables

The Agilent 1100 HPLC System provides efficient mixing and pulse free solvent delivery for consistently rapid and accurate results. Various combinations of modules including pumps and detectors are possible to address certain applications and requirements.  It features a high-speed proportioning valve and pre-configured degasser, which allows low-pressure mixing and a large solvent choice flexibility.

The Agilent Binary Pump provides ensures virtually pulse-free and stable solvent flow, with dual floating positions in series, precisely servo-controlled. The high-speed proportioning valve and preconfigure vacuum degasser allows low-pressure mixing of up to four solvents and the highest flexibility in solvent choices.

The Agilent 1100 Diode Array Detector (DAD) verifies its separation quality with multiple signals, peak purity, and spectral libraries during analytical quantification. The unit can be operated by a running computer or a hand-held controller.

Specifications for Agilent 1100 HPLC System with DAD Detector:

Detection type: 1024-element photodiode array
Light Source: Deuterium and tungsten lamps
Wavelength Range: 190 - 950 nm
Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
Drift: 2 × 10-3AU/hr at 254 nm
Linear Absorbance range: > 2 AU (upper limit)
Wavelength accuracy: ± 1 nm
Slit width: 1, 2, 4, 8, 16 nm
Diode Width:  < 1 nm
Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs

Specifications for Agilent 1100 Binary Pump: 

Flow Range: 0.1 to 5 ml/min
Flow Precision: ≤ 0.07% RSD or ≤ 0.02 min SD
Flow Accuracy: ± 1% or 10 ul/min
Pressure: Operating range 0 to 400 bar (0 to 5880 psi) up to 5 ml/min
Composition Range: 1 to 99% or 5 ul/min per channel
Composition Precision: ≤ 0.5% absolute
Composition Accuracy: ≤ 0.15% RSD at 1 ml/min
Compressibility Compensation: User-selectable, based on mobile phase compressibility
Settable Flow Range: Setpoints 0.001 to 5 ml/min, in 0.001 ml/min increments 



 

The ALT Difference

All Items Tested to
Manufacturer Spec

More Than 12,000
Items in Stock

Up to 1-Year
Warranty

Price Match
Guarantee

50%–80%
off Retail