Category: Chromatography - Gas | Subcategory: GC-MS
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump
Agilent  7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump

Agilent 7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump

ITEM: 32638 In Stock
Price: $97,950.00
Finance for as low as: $2,184.29/mo
Free 90 Day Warranty
One Year Upgrade Available
Tested & Serviced Prior to Shipping

The Agilent 7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump offers outstanding precision, sensitivity, and versatility in gas chromatography-mass spectrometry (GC-MS) instrumentation.

When coupled with the 7890B GC, the Agilent 7010A Triple Quad MS With EI Source offers unparalleled detection capabilities, enabling trace-level analysis of compounds even in complex matrices. With a wide dynamic range and exceptional accuracy, this system delivers reliable quantitative and qualitative data for a broad spectrum of compounds across diverse applications.

The Agilent 7010A Triple Quad MS With EI Source, 7890B GC, 7693 Autosampler, Injector And Pump delivers high-speed data acquisition and processing, combined with rapid chromatographic separations, streamline workflows, maximizing throughput without compromising precision.

The EI (Electron Ionization) source ensures robust ionization of a broad range of compounds, facilitating comprehensive analysis across various sample types and matrices.

**This system includes a computer preloaded with MassHunter Software, monitor, keyboard, mouse, and cables.

7890B GC Features:

  • Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
  • Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
  • Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
  • Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
  • Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
  • Carrier Gas Options: Helium Conservation Module, Hydrogen Sensors and Alternate Carrier Gas Solutions dramatically reduce the amount of helium used to offer flexibility in your laboratory
  • Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
  • Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
    Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
  • Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling

7693A Autosampler Features:

  • 150-sample vial tray allows longer unattended operation
  • Dual simultaneous injection increases lab productivity by doubling sample throughput
  • Fast injection technology minimizes needle discrimination and enables the use of external standards
  • Sandwich injections of three layers eliminate manual error from internal standard, surrogate, or analyte protectant additions
  • Sample heater and mixer dramatically improves high molecular weight chromatographic results
  • Entire tray heating, or cooling to sub-ambient temperatures, meets your lab’s needs
  • Modular design offers the flexibility to easily move the autosampler from GC to GC or start with a single injector and upgrade as needed
  • Priority sample capability eliminates the need to stop a sequence to add the next most important sample
    Barcode reader allows the system to perform specific actions on mismatch, ensuring chain of custody

Agilent 7010A QQQ Specifications:

Ion Source Material: Non-coated, proprietary inert source
Ion Source Temperature: 150°C to 350°C
Filaments: Dual Filaments for EI
Electron Energy: 10 to 300 eV
Mass Filters (2): Proprietary monolithic hyperbolic gold-coated quadrupole
Mass axis stability: < ± 0.10 u over 24 hours (10 to 40°C)
Quadrupole temperature: 106°C to 200°C
Mass Range: m/z 10 to 1,050
Resolution: Selectable, 0.7 to 2.5 Daltons, default tune; Settable, 0.4 to 4.0 Daltons, custom tune
Scan rate: Up to 6,250 u/s
Tuning: Autotune or manual
Detector: Triple-Axis HED-EM with extended-life EM and dynamically ramped-iris
MRM speed: 800 transitions/sec
Minimum MRM dwell: 0.5 msec
Collision cell: Linear hexapole
Collision cell gas: Nitrogen with helium quench gas
Collision energy: Selectable up to 60 eV
Vacuum system: Dual Stage turbomolecular pump; Total gas flow up to 8 mL/min
Software: Agilent MassHunter

Similar Products

Teledyne Tekmar 14-8900-00T Velocity XPT Purge & Trap Sample Concentrator System

VIEW MORE DETAILS

Agilent 7890A GC System With Leco Pegasus High Throughput TOFMS

VIEW MORE DETAILS

Agilent 7890B (G3440B) GC System With 5977E (G7035A) MSD, 7693 (G4514A) Autosampler, (G4513A) Injector

VIEW MORE DETAILS

Agilent 7683B (G2913A) Automatic Liquid Sampler

VIEW MORE DETAILS