Agilent 1260 Series G1316A Thermostatted Column Compartment

Agilent 1260 Series G1316A Thermostatted Column Compartment Image

ITEM: 31215 In Stock

  • Free 90 Day Warranty
  • One Year Upgrade Available
  • Tested & Serviced Prior to Shipping

Or call (860) 691-2213

Agilent 1260 Series G1316A Thermostatted Column Compartment ImageAgilent 1260 Series G1316A Thermostatted Column Compartment ImageAgilent 1260 Series G1316A Thermostatted Column Compartment ImageAgilent 1260 Series G1316A Thermostatted Column Compartment Image

The Agilent Technologies 1260 Series G1316A Thermostatted Column Compartment  is a
stackable temperature-controlled column compartment for LC. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Features:

  • Peltier heating and cooling from 10 degrees below ambient up to 80 °C with high heating and cooling speeds for maximum application flexibility and stability.
  • Holds up to three 30 cm columns and optimized design gives minimum dead volumes and maximum efficiency.
  • Two independently programmable heat exchangers contribute volumes of only 3 µL and 6 µL. 
  • Electronic column- identification module as standard for GLP documentation of column type and major column parameters.

Specifications:
Weight22 lbs. (11.2 kg) 
Dimensions34.5" W x 43.5" D 14" H cm (5.5 x 13.5 x 17 inches)
Line voltage100 – 240 VAC, ± 10 % Wide-ranging capability
Line frequency50 or 60 Hz, ± 5 %
Power consumption320 VA / 150W / 512 BTU Maximum
Ambient operating temperature0–55 °C (32–131 °F)
Ambient non-operating temperature-40 – 70 °C (-40 – 158 °F)
Humidity< 95 % r.h. at 40 °C (104 °F) Non-condensing
Operating altitudeUp to 2000 m (6562 ft)
Non-operating altitudeUp to 4600 m (15091 ft) For storing the module
Safety standardsIEC, CSA, UL
Installation categoryII, Pollution degree 2 For indoor use only
Temperature range10 degrees below ambient to 80 °C
up to 80 °C: flow rates up to 5 mL/min
Temperature stability± 0.15 °C
Temperature accuracy± 0.8 °C
± 0.5 °C With calibration
Column capacityThree 30 cm
Warm-up/cool-down time5 minutes from ambient to 40 °C
10 minutes from 40 – 20 °C
Dead volume3 µL left heat exchanger
6 µL right heat exchanger
CommunicationsController-area network (CAN), RS-232C,
APG Remote: ready, start, stop and
shut-down signals, LAN via other 1260
Infinity module
Safety and maintenanceExtensive diagnostics, error detection
and display (through Instant Pilot and
Agilent data system), leak detection, safe
leak handling, leak output signal for
shutdown of pumping system. Low
voltages in major maintenance areas.
GLP featuresColumn-identification module for GLP
documentation of column type.
HousingAll materials recyclable

 