Category: Electrophoresis | Subcategory: Electrophoresis System

Beckman Coulter PA800 ProteomeLab Protein Characterization System

Beckman Coulter PA800 ProteomeLab Protein Characterization System Image

ITEM: 21655 In Stock

  • Free 90 Day Warranty
  • One Year Upgrade Available
  • Tested & Serviced Prior to Shipping

Or call (860) 691-2213

Beckman Coulter PA800 ProteomeLab Protein Characterization System ImageBeckman Coulter PA800 ProteomeLab Protein Characterization System ImageBeckman Coulter PA800 ProteomeLab Protein Characterization System ImageBeckman Coulter PA800 ProteomeLab Protein Characterization System ImageBeckman Coulter PA800 ProteomeLab Protein Characterization System ImageBeckman Coulter PA800 ProteomeLab Protein Characterization System Image

 

The Beckman Coulter PA800 ProteomeLab Protein Characterization System can identify differences between normal and abnormal states and addresses these differences using the complete line of flow cytometers and immunoassay-based microarrays. Its designed to handle most aspects of the proteomics process including cellular isolation, subcellular fractionation, antigen identification, protein fractionation, protein characterization, data evaluation and ultimately, disease diagnosis.

Specifications for Beckman Coulter ProteomeLab PA 800 System with LIF:
- Electrical data: 100-240V, 50/60Hz; auto-voltage sensing power supply
- Sampling Formats:96-well plates, microfuge tubes, PCR vials, 2ml vials
- Temperature Range: 20° below Ambient to 60°C (minimum setting 4°C)
- Temperature Stability: ±1°C
- Temperature Accuracy: Temperature of environment: ±2°C within the range of ±15°C from ambient; ±3°C outside the range of ±15°C for ambient.
- Relative Fluorescence Units Range: 0 to 1000 RFU
- Dynamic Range (at a dynamic range setting of 1000):  > 10^4
- Sensitivity: 1 x 10^-11M Sodium Fluorescein with a signal-to noise ratio ≥ 2
- Baseline Noise: < 0.005 RFU peak to peak
- Baseline Drift: < 0.2 RFU per hour
- Filters (optional): 
For user supplied lasers: Each laser configuration requires two filters, a laser filter to block stray laser light and an emission filter to select the wavelength of the emitted light. These filters must have an outside diameter of 0.500” (+.000, -.010”) and a thickness not greater than 0.350”; if multiple filters are used in a single channel, the total thickness cannot exceed 0.350”.
- Fiber Cable Length: 6 ft (1.83 m)
- Software Requirements: 32 Karat Software, Version 7.0 or later
- Laser: 3 mW 488 nm (air-cooled) Argon Ion Laser
- Analog Outputs: 
Output 1 is Data Channel 1 and Output 2 is Data Channel 2; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values) Output 3 is Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed
- Max Heat Dissipation to Room: 400 W (1024 BTU/H)
- Ambient Operation Temperature: 15° to 40°C
- Dimensions (W x H x D): 22.38 x 27.13 x 24.13 in (56.83 x 68.9 x 61.28 cm)
- Laser Module Dimensions (W x H x D): 10.25 x 25 x 14.25 in (26.3 x 63.3 x 35 cm)

Specifications for Beckman Coulter ProteomeLab PA 800 System with UV:
- Wavelength Accuracy: 2 nm
- Filter Selection: 200, 214, 254, and 280 nm (standard); three open positions for additional wavelength selections; filter diameter 1/2 inch (127 mm); 0.20 in. thick
- UV Source: Deuterium lamp; 30 W; prealigned
- Wavelength Range: 190 to 600 nm

- LIF 488 NM Laser module 
- LIF Detector Module 
- Diode Array Detector Module 
- Laser Interconnect Module 
- UV Detector Module

Includes computer pre-loaded with software, flat screen monitor, keyboard, mouse and cables.

 

The ALT Difference

All Items Tested to
Manufacturer Spec

More Than 12,000
Items in Stock

Up to 1-Year
Warranty

Price Match
Guarantee

50%–80%