Category: Incubators - Ovens | Subcategory: Incubators
Binder Series BD 23 - Classic.Line Incubator
ITEM: 25642
This product is currently out of stock, please check our complete line of in-stock Incubators by clicking the green link below or give one of the members of our sales team a call today at (860) 691-2213 so we can help you find a suitable replacement.
NEW from manufacturer! Comes with 2 year manufacturer's warranty.
Binder Series BD 23 - Classic.Line Incubator
Designation | Series BD |
Series feature | Incubators Classic.Line with natural convection |
Important characteristics | * Temperature range: room temperature plus 5 °C to 100 °C * APT.line™ preheating chamber technology * natural convection * Adjustable exhaust air flap * Controller with timer functions * Inner door made of tempered safety glass * 2 chrome-plated racks * Units up to 115 liters are stackable * Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm * Computer interface: RS 422 |
Features | * Temperature range: room temperature plus 5 °C to 100 °C * natural convection * Adjustable exhaust air flap * Controller with timer functions * Inner door made of tempered safety glass * Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm |
Text of Series | The BINDER incubator of the BD series with natural convection is the specialist in long-term and stable continuous operation. This incubator is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media or microbiological heating. |
TECHNICAL DATA
Description | BD023-230V * | BD023UL-120V * |
Article Number | 9010-0187 | 9010-0189 |
Performance Data Temperature | ||
Temperature range 5 °C above ambient temperature to [°C] | 100 | 100 |
Temperature variation at 37 °C [± K] | 0.5 | 0.5 |
Temperature fluctuation at 37 °C [± K] | 0.2 | 0.2 |
Heating-up time to 37 °C [min] | 59 | 59 |
Recovery time after 30 seconds door open at 37 °C [min] | 20 | 20 |
Electrical data | ||
Rated Voltage [V] | 230 | 120 |
Power frequency [Hz] | 50/60 | 60 |
Nominal power [kW] | 0.2 | 0.2 |
Unit fuse [A] | 12.5 | 12.5 |
Phase (Nominal voltage) [ph] | 1 | 1 |
Measures - Outer dimensions | ||
Width net [mm] | 435 | 435 |
Height net [mm] | 495 | 495 |
Depth net [mm] | 520 | 520 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Measures - Doors | ||
Unit doors | 1 | 1 |
Measures - Internal Dimensions | ||
Width [mm] | 222 | 222 |
Height [mm] | 330 | 330 |
Depth [mm] | 277 | 277 |
Measures | ||
Interior volume [L] | 20 | 20 |
Net weight of the unit (empty) [kg] | 27 | 27 |
permitted load [kg] | 25 | 25 |
Load per rack [kg] | 12 | 12 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 11 | 11 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
* All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.