Category: Spectroscopy | Subcategory: Spectrophotometer
Biochrom Libra S32PC UV/Vis Spectrophotometer

ITEM: 29050 In Stock


The Biochrom Libra S32PC UV/Vis Spectrophotometer was designed for laboratories seeking GLP, high performance, IQ/OQ certification test plans and outputs to LIMS. It is intended for analytical, pharmaceutical, and research laboratories.
Specifications:
- Wavelength Range: 190 - 1100nm
- Wavelength Accuracy (+/-): 0.7nm
- Wavelength Reproducibility (+/-): 0.2nm
- Lamp Source: Deuterium/Tungsten (PTR)
- Beam: Split Beam
- Optical System: Reference Beam Compensation
- Bandwidth: <1.8nm
- Detector: Dual Solid-State Silicon photodiode
- Photometric Range: -3.000 to 3.000A. -99999 to 99999 conc. units, 0.1 to 200%T
- Stray Light: <0.025%T at 220 and 340nm
- Zero Stability: ± 0.001A/h at 340nm at 0A after warm-up
- Baseline Flatness: N/A
- Method Storage: Up to 50
- Compliance: 21 CFR part 11*, IQ/OQ*
- Data Output: Export to PC, PC Control
- Display: None (PC dependent)
- Data Interface: Serial
- Languages: English, French, German, Italian, Spanish, Russian
- Power Requirement: 90-265V AC, 50/60Hz, 150VA
- Weight: 13Kg (28.6Ib)
- Dimensions (W x D x H): 51 x 37 x 23 cm (20 x 14.6 x 9.1 in.)
- Noise: ± 0.001A near 0A and 0.002A near 2A at 546nm
- Photometric Accuracy: +/- 0.5% or +/-0.003A to 3A at 546nm
- Photometric Reproducibility: within 0.5% of absorbance value to 3.000A (at 546nm)
- Spectral Scanning: Yes
Specifications:
- Wavelength Range: 190 - 1100nm
- Wavelength Accuracy (+/-): 0.7nm
- Wavelength Reproducibility (+/-): 0.2nm
- Lamp Source: Deuterium/Tungsten (PTR)
- Beam: Split Beam
- Optical System: Reference Beam Compensation
- Bandwidth: <1.8nm
- Detector: Dual Solid-State Silicon photodiode
- Photometric Range: -3.000 to 3.000A. -99999 to 99999 conc. units, 0.1 to 200%T
- Stray Light: <0.025%T at 220 and 340nm
- Zero Stability: ± 0.001A/h at 340nm at 0A after warm-up
- Baseline Flatness: N/A
- Method Storage: Up to 50
- Compliance: 21 CFR part 11*, IQ/OQ*
- Data Output: Export to PC, PC Control
- Display: None (PC dependent)
- Data Interface: Serial
- Languages: English, French, German, Italian, Spanish, Russian
- Power Requirement: 90-265V AC, 50/60Hz, 150VA
- Weight: 13Kg (28.6Ib)
- Dimensions (W x D x H): 51 x 37 x 23 cm (20 x 14.6 x 9.1 in.)
- Noise: ± 0.001A near 0A and 0.002A near 2A at 546nm
- Photometric Accuracy: +/- 0.5% or +/-0.003A to 3A at 546nm
- Photometric Reproducibility: within 0.5% of absorbance value to 3.000A (at 546nm)
- Spectral Scanning: Yes