Category: Chromatography | Subcategory: Flash Chromatography System
Biotage Isolera One Model ISO-1SV

ITEM: 25894 In Stock






The Biotage Isolera One, Model ISO-1SV is a high performance flash purification systems. The Isolera One with time, efficiency and cost saving purification runs features that are normally only found on the world’s most expensive high-end chromatography systems. Biotage calls it "the most intelligent flash chromatography system in the world".
Features:
- A touch screen display, which is a solvent-resistant, color LCD screen with a resolution of 800 x 600 pixels. It serves both as a display and as the system’s input device via on-screen touch controls.
- A fraction collector, which collects fractions into a wide variety of collection racks and vessels.
- A pump module, which directs liquid flow through the system.
- An internal detector, which provides the system with information on the light absorbance of the solvents and samples passing through the detector flow cell. (It is also possible to connect an external detector, e.g. Biotage ELSD-1080.)
Specifications: | |
Power | 100-240 VAC, 50/60 Hz, 200VA |
Dimensions | 14" W (one collection tray), 22.7" W (two collection trays), 19.6" D x 23.5" H (35.5/57.7 x 49.7 x 59.6 cm) |
Weight | 66-77 lbs. (30-35 kg.) depending on system configuration |
Location For Use | A laboratory fume hood with capacity to handle leakage of solvents |
Working Temperature | 15°C to 32°C (59°F to 89.6°F) |
Working Humidity | 20% to 95% at room temperature |
Interfaces | LAN port, two USB 2.0 ports, mouse port, VGA port, external detector port, and leak detector port |
Fraction Volume | Programmable from 1 to 9999 ml (Isolera Prime, One, and Four) or 5 to 99999 ml (Isolera LS), depending on rack type |
Max Fraction Number | 192 fractions with no rack change (384 with two collection trays), 13x100 mm racks |
Max Total Volume | 4800 ml with no rack change (9600 ml with two collection trays), 480 ml bottle racks |
Rack Types | 13x100 mm, 16x100 mm, 18x130 mm (for 17.5 x 130 mm test tubes), 16x150 mm, 18x150 mm, 25x150 mm, 120 ml, 240 ml, 480 ml |
Internal Detector Wavelength | 200 nm to 400 nm (variable), 200 to 800 nm (UV-VIS), or 254 nm (fixed) |
Amplitude Range | 0 to 6 AU (Absorbance Units); accuracy of ±0.04 AU |
Flow Cell Optical Path | 0.3 mm |
UV lamp | Deuterium discharge, 25 W |
Tungsten lamp | 10 W (used with the UV-VIS detector) |
Pump Flow Rate Range | 1 to 200 ml/min in 1 ml/min increments |
Pressure Range | 0 to 10 bar (0 to 145 psig) |
Gradient Precision | ±2% |
Display Screen | Solvent Stable 10.4" touchscreen LCD; TFT active matrix; 800 x 600 resolution |