The BioTek’s ELx405UVS Microplate Washer is a deep well washer features a simple to use programming keypad to run multiple onboard protocols along with those created or edited by the user. Its capable of handling 96- and 386- low profile, standard and deep well microplates up to 50mm and features 96 tube Dual-Action manifold for rapid washing. The BioTek ELx405UVS was designed to provide an optimal wash process necessary for cell culture and plasmid DNA preparation along with magnetic and polystyrene bead protocols for various types of laboratories.
Specifications:
- Shaking time: programmable up to 60 minutes at multiple speeds
- Onboard Software: Create, edit and run multiple protocols
- Soaking: Programmable up to 60 minutes
- Manifold Types: 96 Tube Dual Action manifold for 96- & 384-well washing
- Volume Range: 50 to 3000 microliter increments
- Wash Cycles: 1 -10
- Buffer/reagent Selection: Auto switching module for up to 4 buffers (option)
- Supply bottle: 4 L
- Dispense Precision: ≤3% CV: 300 µL/well (96-well washing)
- Residual Volume: <2 µL/well (standard & deep well 96-well plates)
- Wash Speed:
96-wells, 300 µL/well, 3 cycles: <30 seconds
384-wells, 100 µL/well, 3 cycles: <80 seconds
- Flow Rates:
High flow to low flow
Optimized rates for cell assays:
- Sterilization: Chemical
- Vacuum Filtration:
Selectable: Approximate final at 30 seconds:
Lowest: -38 mmHg
Low: -113 mmHg
Medium: -200 mmHg
High: -390 mmHg
Highest: -506 mmHg
Vacuum filtration time range: 5 to 999 seconds
- Dimensions (D x W x H): 17” x 14” x 10” (43.2 x 35.6 x 25.4 cm)
- Weight: 30 lb. (13.5 kg)
Specifications:
- Shaking time: programmable up to 60 minutes at multiple speeds
- Onboard Software: Create, edit and run multiple protocols
- Soaking: Programmable up to 60 minutes
- Manifold Types: 96 Tube Dual Action manifold for 96- & 384-well washing
- Volume Range: 50 to 3000 microliter increments
- Wash Cycles: 1 -10
- Buffer/reagent Selection: Auto switching module for up to 4 buffers (option)
- Supply bottle: 4 L
- Dispense Precision: ≤3% CV: 300 µL/well (96-well washing)
- Residual Volume: <2 µL/well (standard & deep well 96-well plates)
- Wash Speed:
96-wells, 300 µL/well, 3 cycles: <30 seconds
384-wells, 100 µL/well, 3 cycles: <80 seconds
- Flow Rates:
High flow to low flow
Optimized rates for cell assays:
- Sterilization: Chemical
- Vacuum Filtration:
Selectable: Approximate final at 30 seconds:
Lowest: -38 mmHg
Low: -113 mmHg
Medium: -200 mmHg
High: -390 mmHg
Highest: -506 mmHg
Vacuum filtration time range: 5 to 999 seconds
- Dimensions (D x W x H): 17” x 14” x 10” (43.2 x 35.6 x 25.4 cm)