Labe Equipment Sale

Category: Hoods | Subcategory: Biosafety Cabinets

Labconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft.

Labconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. Image

ITEM: 30463

This product is currently out of stock, please check our complete line of in-stock Biosafety Cabinets by clicking the green link below or give one of the members of our sales team a call today at (860) 691-2213 so we can help you find a suitable replacement.

 

Labconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. ImageLabconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. ImageLabconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. ImageLabconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. ImageLabconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. ImageLabconco Purifier Delta Series Class II, Type B2 Total Exhaust Biological Safety Cabinet, 4 Ft. Image

Every component of the Labconco Purifier Delta Series Class II B2 Biosafety Cabinet has been optimized for peak performance. The Air-Wave™ Entry System, consisting of the curved design of the side posts, air foil and sash handle, ensures smoother airflow into the work area minimizing turbulence and enhancing containment. Internally, we’ve designed a ramped steel plenum that captures the recirculated air, stabilizes it, and then distributes it evenly across the HEPA filters and the work area. Laminar airflow is idealized and true, not zoned. The Air-Wave Entry System and plenum work together to provide superior airflow that protects the operator and prevents cross contamination.

The exclusive Contain-Air™ Negative Pressure Channel, located behind the sash, maximizes containment at the air gap between the top of the sash opening and the cabinet wall. Any hazardous aerosol created in the work area that may travel upward toward the top of the sash is drawn into the channel by negative pressure and then forced through a HEPA filter. Unreliable seals and gaskets, which could degrade or drag on the contaminated glass, are not used.

 

Specifications:
Model InfoClass II, Type B2; Model 36210, Cat. 3621004, rev. M
Nominal Width4 feet
Sash Opening8"
Exhaust Volume743-771 CFM
Electrical Requirements115 V, 60 Hz, 12 A, 1 PH
Power Cord & Plug115 volts, 15 amps
Light(s)Fluorescent, Ultraviolet
Service Fixture(s)1
Shipping Weight736 lbs. (334 kg)

The ALT Difference

All Items Tested to
Manufacturer Spec

More Than 12,000
Items in Stock

Up to 1-Year
Warranty

Price Match
Guarantee

50%–80%
off Retail