The LI-COR Odyssey Fc Imager captures and analyzes fluorescence images with near-infrared (NIR) fluorescence detection, providing exceptional sensitivity and accuracy.
The LI-COR Odyssey Fc Imager boasts an impressive dynamic range, enabling simultaneous detection and quantification of multiple fluorophores in a single sample. No more sequential imaging or worries about signal bleed-through – this imager effortlessly captures distinct fluorescence signals, revolutionizing your experimental workflow.
Featuring a versatile imaging platform, the LI-COR Odyssey Fc Imager allows for a wide range of applications, from Western blot analysis and multiplex protein detection to DNA fragment analysis and cell-based assays. Its intuitive software interface offers seamless control and analysis, simplifying your experiments and streamlining data acquisition and interpretation.
Specifications:
Operating Conditions: For Indoor use only; operating temperature 15 - 35 °C and dew point <22 °C, non-condensing; maximum operating temperature may be reduced at elevations above 2000 m.
Environmental Conditions: Pollution Degree 2.
Dynamic Range: 22 bit (>6 logs)
Depth of Field for Best Sample Focus: 6 mm
Patented FieldBrite Technology: CV <3%600 Channel Light Source: Light source at 520 nm700 Channel Laser Source: Solid-state Laser Diode at 685 nm800 Channel Laser Source: Solid-state Laser Diode at 785 nm
Laser Lifetime: 20,000 hours
Detector Type: Low-noise CCD. Thermoelectrically cooled.
Acquisition Times: 600, 700 and 800 nm channels: 30 s, 2 min, 10 min plus advanced variable time feature. Chemiluminescence channel: 30 s, 2 min, 10 min, 60 min plus advanced variable time feature.
Focusing: None needed.
Sensitivity: Similar to Odyssey® CLx Imaging System
Dyes: Optimized for LI-COR® IRDye® 680RD and IRDye® 800CW reagents, and chemiluminescent substrates.
Image Display Options: Pseudocolor, positive and negative grayscale, single color (red, green or blue), or two colors with overlapping fluorescence displayed in a third color.
Capacity: One imaging tray containing one blot or gel.
Field of View: 10 cm D × 12 cm W (3.9” D × 4.7” W) at the surface of the imaging bed.
Power Requirements: Universal input range is between 100-127 VAC and 200-240 VAC (voltage fluctuations not to exceed 10% of the nominal voltage); 50/60 Hz; at 120V, 4 Amp maximum; at 120V, 0.3 Amp typical when idle. Overvoltage Category II.
Computer Connection Cable: Cat. 5e RJ45, 10BASE-T/100BASE-TX/1000BASE-T. Use only the supplied cable.
Dimensions: 16.3" W × 18.5" D 26.5" H inches (41.4 x 47 x 67.3 cm). Depth with imaging drawer open is 23.5" (59.7 cm).