Category: Chromatography - Gas | Subcategory: Autosamplers - Purge/Trap

O.I.Analytical 4560 Sample Concentrator

O.I.Analytical 4560 Sample Concentrator Image

ITEM: 20607

This product is currently out of stock, please check our complete line of in-stock Autosamplers - Purge/Trap by clicking the green link below or give one of the members of our sales team a call today at (860) 691-2213 so we can help you find a suitable replacement.

 

O.I.Analytical 4560 Sample Concentrator ImageO.I.Analytical 4560 Sample Concentrator ImageO.I.Analytical 4560 Sample Concentrator Image

The O.I. Analytical Model 4560 Sample Concentrator thermally traps and desorbs organic compounds for GC and GC/MS analysis.

The Model 4560 Purge-and-Trap Sample Concentrator collects and transfers volatile organic compounds to a GC or GC/MS for analysis. It is specifically designed to purge volatiles from water, soil, and air for concentration onto a sorbent trap in compliance with USEPA protocol. The sample transfer line connects directly to the column or through an optional Low-Dead-Volume InjectorTM to the GC column in an analytical system.

Features:

• Built-in Cyclone Water ManagementTM minimizes the amount of water transferred to the analytical column and detector.

• Uses 5- and 25-mL frit and needle spargers and disposable tube spargers, using the same length needle and “wide-neck” 18-mm mount.

• Handles sample foaming and spillover through a removable particle foam filter in the sample inlet.

• Provides controlled temperature of each heated zone.

• Processor-controlled and fully interactive via the RS-232-C communication port.

• Basic operational sequence is controlled by key entry; operator interface is simple to use and vacuum-fluorescent display is easy to read. 2 Model 4560 Sample Concentrator Operator’s Manual Rev. 2.3

• Up to 14 sets of run settings can be saved, loaded as files, and even sequenced during a multisampler run.

• Rapid trap heating (900°C/min) and cooling (250°C/min) optimizes chromatography and reduces run times.

• All lines contacting the sample are inert and impermeable to gases.

• Incorporates power-up self-test and diagnostics messages.

• Optional Internal Carrier Flow Controller allows all gases (purge and carrier) to be provided by and monitored through the sample concentrator.

• Incorporates BCD inputs for multisampler position monitoring.

The ALT Difference

All Items Tested to
Manufacturer Spec

More Than 12,000
Items in Stock

Up to 1-Year
Warranty

Price Match
Guarantee

50%–80%
off Retail