Omega CL900-110 Hot Point Dry Block Probe Calibrator, Single Well

ITEM: 28446
This product is currently out of stock, please check our complete line of in-stock Calibrator by clicking the green link below or give one of the members of our sales team a call today at (860) 691-2213 so we can help you find a suitable replacement.



The Omega CL900-110 Hot Point Dry Block Probe Calibrator allows calibration of thermocouple and RTD probes quickly and easily with accuracy to 0.9°C (1.5°F). An integral RTD sensor assures high measurement accuracy and repeatability. A built-in microprocessor-based PID digital controller assures exceptional stability. Setpoint and actual temperature are displayed simultaneously. Temperature can be set in one-degree increments from 22°C (40°F) above ambient to 482°C (900°F).
The CL900 calibrator accepts a variety of standard and metric optional inserts which are available in 4 and 6" depths and for probe diameters from 1⁄8" to 3⁄8". An undrilled insert is also available. The CL900 comes complete with a 1⁄4" diameter, 6" deep insert well and insert block tongs. Additional inserts can be CL900/950 Series hot point Dry Block Probe Calibrators ordered separately as required for other diameter probes. 6" depth inserts are used for probes 7" and longer; 4" depth inserts are used for probes 5" and longer.
The CL950 calibrator features a built-in well with 5 ports sized to accommodate a 1⁄16, 1⁄8, 3⁄16, and two 1⁄4" diameter probes. The multiport design allows for the use of a calibrated or NIST-traceable probe and meter to be used as a standard while calibrating other probes. The 5 port design also allows for calibration of more than 1 probe at a time, and eliminates the need for separate insert wells.
Specifications: | |
Temperature Range | Ambient 22°C to 482°C (40°F to 900°F) |
Operating Ambient Temperature Range | 5°C to 38°C (40°F to 100°F) |
Control Stability | ±0.3°F or better |
Temperature Uniformity Within the Bottom 1" of the Test Well | 6" Test Well Inserts: 0.3% 4" Test Well Inserts: ±0.4% |
Max Probe Immersion | 6" Test Well Inserts: 150 mm (6") 4" Test Well Inserts: 100 mm (4") |
Control | Microprocessor-based PID digital controller with data retention |
Power | 110 to 125 Vac, 50/60 Hz, 1050 W; 220 Vac, 50/60 Hz, 1050 W |
Weight | 22.3 lbs. (10.1 kg) |
Dimensions | 8.5" W x 12.25" D x 11.75" H (21.6 x 31.1 x 30 cm) |
Compatible Inserts for CL900 Series (not included) | |
Model No. | Description |
CL901 | Insert, 1⁄8 diameter x 4" deep test well |
CL901-M | Metric insert, 2 diameter x 101.6 mm deep test well |
CL902 | Insert, 1⁄8 diameter x 6" deep test well |
CL902-M | Metric insert, 2 diameter x 152.4 mm deep test well |
CL903 | Insert, 3⁄16 diameter x 4" deep test well |
CL903-M | Metric insert, 3 diameter x 101.6 mm deep test well |
CL904 | Insert, 3⁄16 diameter x 6" deep test well |
CL904-M | Metric insert, 3 diameter x 152.4 mm deep test well |
CL905 | Insert, 1⁄4 diameter x 4" deep test well |
CL905-M | Metric insert, 4.5 diameter x 101.6 mm deep test well |
CL906 | Insert, 1⁄4 diameter x 6" deep test well |
CL906-M | Metric insert, 4.5 diameter x 152.4 mm deep test well |
CL907 | Insert, 5⁄16 diameter x 4" deep test well |
CL907-M | Metric insert, 6 diameter x 101.6 mm deep test well |
CL908 | Insert, 5⁄16 diameter x 6" deep test well |
CL908-M | Metric insert, 6 diameter x 152.4 mm deep test well |
CL909 | Insert, 3⁄8 diameter x 4" deep test well |
CL910 | Insert, 3⁄8 diameter x 6" deep test well |
CL911 | Insert, undrilled |