Teledyne Isco CombiFlash Rf 200 Automated Flash Chromatography System

Teledyne Isco CombiFlash Rf 200 Automated Flash Chromatography System Image

ITEM: 31060 In Stock

  • Free 90 Day Warranty
  • One Year Upgrade Available
  • Tested & Serviced Prior to Shipping

Or call (860) 691-2213

Teledyne Isco CombiFlash Rf 200 Automated Flash Chromatography System ImageTeledyne Isco CombiFlash Rf 200 Automated Flash Chromatography System Image

The Teledyne Isco CombiFlash Rf 200 Flash Chromatography System gives you high-productivity automation, programmable gradients, UV detection and peak separation, and automatic detection of columns and collection tube racks. Its small size makes it a great "personal system" and well suited for operation within chemical hoods and other limited indoor spaces.

The CombiFlash Rf 200 can be configured as a 5–200 mL/min (delivery flow rate), 200 psi system that forms a binary gradient by automatically selecting two solvents from four inlets. This configuration has an automatic, self-cleaning injection valve for sample introduction, and full-spectrum UV (200–360 nm) or UV-vis (200–780 nm) detection with secondary wavelength monitoring. An internal air pump is used for post-run column air purging, active solvent level sensing, and waste full bottle detection.

 

Specifications:
Dimensions14.1" W x 17" D x 24" H (36 x 43 x 61 cm)
Weight54 lbs. (24.5 kg)
Power100 - 240 VAC, 50/60 Hz, 2.0A
Ambient Temperature20 to 40 °C (maximum temperature must be at least 15 °C below the boiling point of the solvent)
Humidity (when connected to power)95% relative humidity maximum at 20 to 40 °C
Flow Rate Range5 to 200 mL/min
Flow Rate Accuracy (tested with water at 138 kPa or 20 psi)±5%
Pressure LimitUp to 1379 kPa (200 psi; column dependent)
Pressure Accuracy5% of full scale
Gradient FormationBinary gradient from A1, A2, and B1, B2 solvent inlets. Solvent selection can be automatically controlled by the method.
Gradient Accuracy±1% of full scale
Peak Detection ModesSlope or threshold
Flow Cell Pathlength0.1mm, ±25%
UV Detection Wavelength200 to 360 nm, optional 200 to 780 nm UV-Vis
Monitor Wavelength with Purity Ratio200 to 360 nm, optional 200 to 780 nm UV-Vis
Wavelength Accuracy±5 nm
Fraction Accuracy±[2mL + (flow rate/60)]
Pollution Degree2
Installation CategoryII
Maximum Altitude2000 meters