Category: Meters | Subcategory: Multimeters

TSI VelociCalc Plus Multi-Parameter Ventilation Meter, Model 8386A

TSI VelociCalc Plus Multi-Parameter Ventilation Meter, Model 8386A Image

ITEM: 31721

This product is currently out of stock, please check our complete line of in-stock Multimeters by clicking the green link below or give one of the members of our sales team a call today at (860) 691-2213 so we can help you find a suitable replacement.

 

TSI VelociCalc Plus Multi-Parameter Ventilation Meter, Model 8386A ImageTSI VelociCalc Plus Multi-Parameter Ventilation Meter, Model 8386A Image

The TSI VelociCalc Plus Multi-Parameter Ventilation Meter, Model 8386A simultaneously measures and data logs several ventilation parameters using a single probe with multiple sensors. The ventilation meter measures temperature, velocity and pressure. It also features automatic calculation of flowrate and automatic conversion between actual and standard velocity readings.

Specifications:

Velocity From Thermal Sensor: Range 0 to 9,999 ft/min (0 to 50 m/s)
Accuracy: ±3.0% of reading or +±3 ft/min
(± .015 m/s), whichever is greater
Resolution: 1 ft/min (0.01 m/s)
Velocity From a Pitot Tube, Range: 250 to 15,500 ft/min (1.27 to 78.7 m/s) Accuracy: ±1.5% at 2,000 ft/min (10.16 m/s)
Resolution: 1 ft/min (0.01 m/s)
Volumetric Flowrate: Actual range is a function of maximum velocity, pressure, duct size, and K factor
Duct Size Range :1 to 250 in. in increments of 0.1 in. (1 to 635 cm in increments of 0.1 cm)
Static/Differential Pressure Range: 5-5 to +15 in. H2O (-9.3 to +28.0 mmHg,
or -1245 to +3735 Pa)
Accuracy: ±1% of reading ±0.005 in. H2O, (±1 Pa or ±0.01 mmHg) ±0.02%/°F (±0.03%/°C)
Resolution: 0.001 in. H2O (1 Pa, 0.01 mmHg)
Operating Temperature, Probe: -10°C to 60°C
Operating Temperature Range: 5 to 45°C
Storage Temperature Range: -20 to 60°C
Resolution: 0.1°C
Accuracy: ±0.3°C
Relative Humidity Range: 0 to 95% rh
Accuracy: ±3% rh
Resolution 0.1% rh
Dewpoint Temperature Range: -15°C to 49°C
Resolution: 0.1°C
Heat Flow Range: Range Function of Flow Rate, Temperature, Humidity
and Barometric Pressure
Measurements Sensible Heat Flow, Latent Heat Flow,
Available Total Heat Flow and Sensible Heat Factor
Units Measured BTU/h, kW
Logging Capabilities: Up to 1394 samples and 275 test id’s (one sample can contain up to all eleven measurement types)
Intervals 2 sec, 5 sec, 10 sec, 15 sec, 20 sec, 30 sec, 60 sec, 2 min, 5 min, 10 min, 15 min, 20 min, 30 min, 60 min

The ALT Difference

All Items Tested to
Manufacturer Spec

More Than 12,000
Items in Stock

Up to 1-Year
Warranty

Price Match
Guarantee

50%–80%
off Retail