Specifications: 

  • Wavelength range: 190 to 700 nm
  • Bandwidth: <5 nm
  • Wavelength accuracy: +1.0 nm
  • Wavelength repeatability: +0.1 nm
  • Single λ dry noise: <5 µAU (at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)
  • Wet noise: <8 µAU (at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)
  • Dual channel noise (dry): <35 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)
  • Dual channel noise (wet): <45 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)
  • Linearity: <5% at 2.5 AU, propylparaben at 257 nm
  • Drift: 1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)
  • Thermal drift: 1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)
  • Sensitivity setting range: 0.0001 to 4.0000 AUFS
  • Filter setting range: 
    • Single-wavelength: 0.1 to 5.0 seconds
    • Dual-wavelength: 1 to 50 seconds
  • Time-constant: To 5.0-second Hamming filter
  • Digital data rates:
    • 1,2,5,10,20,40,80 Hz (single channel)
    • 1,2 Hz (dual channel)
  • Analog output data rates (single λ mode):
    • 10,20,40,80 Hz (channel A)
    • 10 Hz only (channel B)
  • Lamp source: 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
  • Second-order filter: Automatic for wavelengths > 370 nm
  • Wavelength calibration filter: Erbium filter, used at startup or on demand
  • Flow cell: TaperSlit flow cell design
  • Nitrogen purge: Purge fitting present on optics bench
  • Path length: 10 mm (standard analytical)
  • Cell volume: 10 µL (standard analytical)
  • Pressure limit: 6895 kPa (69 bar,1000 psi)
  • Materials: 316 stainless steel, fused silica, Tygon
  • Operating temperature: 4 to 40 °C (39 to 104 °F)
  • Operating humidity: 20% to <95%, noncondensing
  • Shipping and storage: -30 to +60 °C
  • Shipping and storage humidity; 0% to <95% noncondensing

 

 

 