Category: HPLC, UPLC, & LC/MS | Subcategory: LC-MS / LC-MS/MS | Manufacturer: Waters
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System
Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System

Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System

ITEM: 30410 Out of Stock
Price: $0.00
Your Trusted Source for Used Lab Equipment
Free 90 Day Warranty
Up to 3 Year Warranty Upgrade Available
Tested & Refurbished Prior to Shipping

Out of stock

The Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System including model 186015006 Sample Manager, model 186015030 Photo Diode Array Detector, model 186015001 Binary Solvent Manager, model HTCH Degasser, & Solvent Tray is one of the most sensitive, exact-mass, quantitative and qualitative benchtop mass spectrometry systems available.

Xevo G2:

The Waters Xevo G2 QTof Quadrupole Time-of-Flight Mass Spectrometer With Acquity UPLC System features Intellistart Technology and Z-Spray ESI LockSpray Ion Source is made for the scientist who needs to identify, quantify and confirm the broadest range of compounds in the most complex and challenging samples.

The Xevo G2 delivers not only conventional MS and MS/MS methots of data acquisition, it also has the ability to perform UPLC/MS to collect the maximum amount of data from a single analysis.  UPLC/MS datasets provide a comprehensive digital record of your sample.  The system incorporates IntelliStart Technology, for automated system optimization and status monitoring, ensuring that the highest quality data is routinely available to all levels of operator.

The Xevo G2 is equipped with a high resolution, high stability quadrupole analyzer (MS1), plus pre-filters to maximize resolution and transmission while preventing contamination of the main analyzers. The instrument is also equipped with a high performance oaTof mass analyzer (MS2) with a mass range up to m/z 100,000 and a resolving power of > 22,500 FWHM.

 

SpecificationsXevo G2:
Dimensions27″ W x 34.4″ D x 59.8″ H (68.7 x 87.3 x 152 cm)
Regulatory ApprovalsCE and NRTL
TOF Mass Rangem/z 20 to 100,000
Quadrupole mass range, non resolving modem/z 20 to 16,000
Quadrupole mass range, resolving modem/z 20 to 4,000
Data acquisition rateUp to 30 spectra per second
Mass measurement accuracyBetter than 1 ppm RMS
Mass resolution> 22,500 FWHM
Power200-240 V, 50-60 Hz, 1.1 kW
Acquity System Power100-240 V, 50-60 Hz

 

ACQUITY UPLC System

UPLC Technology, which has been adopted successfully in laboratories around the world for the most demanding separations, is highly robust, dependable, and reproducible.

  • Work at higher efficiencies with a much wider range of linear velocities, flow rates, and backpressures
  • Higher flow rates and increased throughput result in superior resolution and sensitivity
  • Eliminate significant time and cost per sample, while improving quality of results
  • Benefit from Waters’ patented sub-2-μm hybrid particle chemistry.

The ACQUITY UPLC System eliminates significant time and cost per sample from your analytical process while improving the quality of your results. By outperforming traditional or optimized HPLC, this technology allows chromatographers to work at higher efficiencies with a much wider range of linear velocities, flow rates, and backpressures.

UPLC Technology, which has been adopted successfully in laboratories around the world for the most demanding separations, is highly robust, dependable, and reproducible. What differentiates the holistic design of ACQUITY UPLC systems is Waters’ patented sub-2-μm hybrid particle chemistry, which offers significant benefits over today’s HPLC systems equipped with standard 5-μm particle chemistries.

The ACQUITY UPLC System, used on its own or paired with Waters optical and MS detection technologies, provides unique end-to-end solutions for all industries and applications, including: ADME screening, food safety, bioanalysis, clinical, metabolite identification, metabonomics, method development, opens access, and routine quality screens. Since its invention, ACQUITY UPLC Technology has enabled analytical chemists to reach far beyond conventional HPLC separations.

Features of the ACQUITY UPLC System:

  • Comprehensive system components, including the ACQUITY UPLC Sample Organizer, Column Manager and Heater/Cooler, Binary Solvent Manager and Sample Manager, for customized throughput and condition requirements
  • Easy HPLC to UPLC method conversion with the ACQUITY UPLC console calculator
  • Support for existing HPLC methods
  • Predictive system support with Connections INSIGHT® remote intelligent services
  • Chemistries and formats to suit specific analytical tasks, including ACQUITY UPLC 1.7 μm columns, VanGuard pre-columns or ACQUITY UPLC HSS and HSS T3 1.8 μm columns
  • Extended detection capabilities with ACQUITY UPLC Fluorescence (FLR), Tunable UV (TUV), Photodiode Array (PDA), Evaporative Light Scattering (ELS), and Refractive Index (RI) detectors to single, tandem, and time-of-flight mass spectrometers
  • Easily compatible with third-party MS solutions (ABI/MDS SCIEX, Bruker Daltonics, and Thermo Fisher Scientific)

 

SpecificationsPDA Detector:
Wavelength Range190 to 800 nm
Light SourceIntelligent Technology Deuterium Lamp
Wavelength Accuracy±1 nm
Linearity RangeDeviation at 2.0 AU ≤5%, propylparaben, at 257nm
Optical Resolution1.2nm
Digital Resolution1.2 nm/pixel
Baseline Noise± µAU, 230 nm, 2 Hz, 2 s, wavelength compensation 310 to 410, WET (2D channel)
Drift≤1.0 x 10-3/AU/hour/°C
Flow Cell DesignLight-guiding UPLC intelligent technology flow cell
Pathlength10 mm (analytical cell)
Cell Volume500 nL (analytical cell)
Wetted Materials316 stainless steel, fused silica, Teflon AF, PEEK
Data AcquisitionUp to 80 Hz
Pressure Limit1000 psi
Unattended OperationLeak sensors, full diagnostic data captured through console software
Dimensions13.5″ W x 23.9″ D x 7.6″ H (34.3 x 60.7 x 19.4 cm)
Weight30 lbs. (13.6 kg)
Operating Temperature4 – 40°C (39 – 104 °F)
Operating Humidity20% to <90% RH non-condensing
ComplianceCE Mark CSA C-tick and UL
Power100 – 240 VAC, 50/60 Hzx, 185 VA (nominal)

 

SpecificationsBinary Solvent Manager:
Number of SolventsUp to four, in combination of two, A1 or A2 and B1 or B2
Solvent ConditioningIntegrated vacuum degassing, six lines with two allocated for the injector needlewash/purge solvents
Gradient FormationHigh pressure mixing, binary gradient
Gradient Profiles11 gradient curves [including linear, step (2), concave (4), and convex (4)]
Primary Check ValvesIntelligent Intake Valves
Flow Accuracy±1.0% of set flow rate at 0.500 mL/min as per Systems QT
Flow Precision0.075% RSD or 0.01 min SD, (0.2 to 2.0 mL/min), whichever is greater using premixed solvent
Composition Ripple (baseline noise)<1.0 mAu
Pump Compositional Precision<0.15% RSD or 0.02 min SD, whichever is greater
Pump Compositional Accuracy±0.5% absolute from 5 to 95%, 0.2 to 2.0 mL/min
Compressibility CompensationAutomatic, no user intervention required
PrimingWet priming runs at a flow rate of 4 mL/min
Pump Seal WashEquipped with a programmable active wash system to flush the rear of the high pressure seals and the plungers
Flow RampingAutomatic
Primary Wetted Materials316L stainless steel, UHMWPE blend, MP35N, titanium alloy, gold, sapphire, ruby, zirconia, Nitronic 60, DLC, fluoropolymer PEEK, and PEEK blend
Mixing Options50 uL standard; 100 uL and 380 uL optional

 

SpecificationsSample Manager:
Number of Sample PlatesTwo
Maximum Sample Capacity768 in two 384-well plates*
Number of Sample Injections1 to 99 injections per sample
Injection Volume Range0.1 to 50.0 iJL, in 0.1 iJL increments, partial or full loop mode; 10ul loop is standard
Sample Delivery Precision(Full Loop Injection Mode)<0.3% RSO, full loop, standard lO-iJL loop (default wash/purge conditions), per Waters AQT/SystemsQT protocol
Sample Delivery Precision(PLNO Injection Mode)<1% RSO within 20% to 75% of loop volume for 1, 2, 5, 10, 20, and 50-iJL loops, UV detection
Injector Linearity>0.999 coefficient of deviation (from 20% to 75%, partial loop overfill mode (PLNO injection mode), per Waters’ AQT/SystemsQT protocol
Sample Temperature Control0 to 40.0 ·C, settable in 0.1 ·C increments (assumes an ambient temperature of 25.0 ·C)**
Injection Cycle Time<15 sec between multipe injections with “load ahead” enabled; 30 sec with single weak wash, lO-iJL loop, pressure assist mode
Sample ProbeXYZZ based needle-in-needle design
Minimum Sample Required5 uL residual, using maximum recovery 2-mL vials (zero offset)
Wash SolventsTwo degassed: strong solvent and weak wash solvent, programmable to suit application
Sample Carryover<0.005% or <2.000 nL, whichever is greater
Advanced OperationsLoop off-line mode, load ahead
Unattended OperationLeak sensors, full diagnostic data control captured through console software
Primary Wetted MaterialTitanium alloy, 316 stainless steel, fluoropolymer, fluoroelastomer, PPS alloy, PEEK alloy, PPS, PEEK, OLC coating, gold

*expandable to up to 8,448 samples with optional Sample Organizer

**At an ambient temperature of 21.0 ·C or lower the sample manager will maintain the temperature of the sample compartment down to 4.0 ·C with a tolerance of -2.0/+6.0 ·C, when configured with the maximum number of vials and/or plates

Please note: system includes vacuum pump.

Similar Products

Used Lab Equipment - PerkinElmer LC 235C Diode Array Dectector 1

PerkinElmer LC 235C Diode Array Dectector

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series G1330B ALS Therm 3

Agilent 1100 Series G1330B ALS Therm

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series HPLC System With G1311 Quat Pump, G1313 ALS, G1315 DAD 5

Agilent 1100 Series HPLC System With G1311 Quat Pump, G1313 ALS, G1315 DAD

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series G1314A Variable Wavelength Detector (VWD) 7

Agilent 1100 Series G1314A Variable Wavelength Detector (VWD)

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1200 Series HPLC System 9

Agilent 1200 Series HPLC System

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series G1311A QuatPump 11

Agilent 1100 Series G1311A QuatPump

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series HPLC System with G1365A MWD 13

Agilent 1100 Series HPLC System with G1365A MWD

VIEW MORE DETAILS
Used Lab Equipment - Waters 600 MultiSolvent Delivery System 15

Waters 600 MultiSolvent Delivery System

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series G1330A ALS Therm 17

Agilent 1100 Series G1330A ALS Therm

VIEW MORE DETAILS
Used Lab Equipment - Agilent 1100 Series G1315B DAD Diode Array Detector 19

Agilent 1100 Series G1315B DAD Diode Array Detector

VIEW MORE DETAILS