Binder Series ED 115 – Avantgarde.Line Drying and Heating Chamber
| Designation | Series ED |
| Series feature | Drying and heating chambers Avantgarde.Line with natural convection |
| Important characteristics | * Temperature range: ambient temperature plus 5 °C to 300 °C * High temperature accuracy thanks to APT.line™ technology * Natural convection * Controller with LCD display * Electromechanical control of the exhaust air flap * 2 chrome-plated racks * Units up to 115 L are stackable * Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm * Ergonomic handle design * USB port for recording data |
| Features | * Temperature range: ambient temperature plus 5 °C to 300 °C * Natural convection * Controller with LCD display * Electromechanical control of the exhaust air flap * Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm * Excellent temporal and spatial temperature accuracy and high energy efficiency |
| Text of Series | The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 °C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying. |
TECHNICAL DATA
| Description | ED115-230V * | ED115UL-120V * |
| Article Number | 9010-0335 | 9010-0336 |
| Performance Data Temperature | ||
| Temperature range 5 °C above ambient temperature to [°C] | 300 | 300 |
| Temperature variation at 150 °C [± K] | 1.5 | 1.5 |
| Temperature fluctuation at 150 °C [± K] | 0.4 | 0.4 |
| Heating-up time to 150 °C [min] | 45 | 45 |
| Recovery time after 30 seconds door open at 150 °C [min] | 16 | 16 |
| Electrical data | ||
| Rated Voltage [V] | 230 | 120 |
| Power frequency [Hz] | 50/60 | 60 |
| Nominal power [kW] | 1.25 | 1.35 |
| Unit fuse [A] | 6.3 | 12.5 |
| Phase (Nominal voltage) [ph] | 1 | 1 |
| Measures – Outer dimensions | ||
| Width net [mm] | 710 | 710 |
| Height net [mm] | 735 | 735 |
| Depth net [mm] | 605 | 605 |
| Wall clearance back [mm] | 160 | 160 |
| Wall clearance sidewise [mm] | 100 | 100 |
| Measures – Doors | ||
| Unit doors | 1 | 1 |
| Measures – Internal Dimensions | ||
| Width [mm] | 510 | 510 |
| Height [mm] | 530 | 530 |
| Depth [mm] | 425 | 425 |
| Measures | ||
| Interior volume [L] | 114 | 114 |
| Net weight of the unit (empty) [kg] | 54 | 54 |
| permitted load [kg] | 150 | 150 |
| Load per rack [kg] | 30 | 30 |
| Environment-specific data | ||
| Energy consumption at 150 °C [Wh/h] | 245 | 245 |
| Fixtures | ||
| Number of shelves (std./max.) | 2/5 | 2/5 |
* All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.