Category: Incubators - Ovens | Subcategory: Environmental Chambers | Manufacturer: Binder
Binder  Series KBWF 720 – Growth Chamber
Binder  Series KBWF 720 – Growth Chamber
Binder  Series KBWF 720 – Growth Chamber
Binder  Series KBWF 720 – Growth Chamber
Binder  Series KBWF 720 – Growth Chamber
Binder  Series KBWF 720 – Growth Chamber

Binder Series KBWF 720 – Growth Chamber

ITEM: 25708 Out of Stock
Price: $0.00
Your Trusted Source for Used Lab Equipment
Free 90 Day Warranty
Up to 3 Year Warranty Upgrade Available
Tested & Refurbished Prior to Shipping

Out of stock

NEW from manufacturer!  Comes with 2 year manufacturer’s warranty.

Binder Series KBWF 720 – Growth Chamber

DesignationSeries KBWF
Series featureGrowth chambers with light and humidity
Important characteristics* Temperature range: 0 °C to 70 °C
* Temperature range with light: 10 °C to 60 °C
* Humidity range: 10 % to 80 % RH
* positionable illumination cassettes, each with 5 fluorescent tubes
* APT.line™ preheating chamber technology
* Adjustable fan speed
* Humidity regulation with capacitative humidity sensor and vapor humidification
* Intuitive touchscreen controller with time-segment and real-time programming with internal data recording
* Display via color LCD monitor
* Tight-sealing inner door made of safety glass (ESG) with special TIMELESS coating
* stainless steel racks
* Access port with silicone plug, 30 mm, left
* Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
* Computer interface: Ethernet
* Door heating
Features* Temperature range: 0 °C to 70 °C
* Humidity range: 10 % to 80 % RH
* Humidity regulation with capacitative humidity sensor and vapor humidification
* Positionable illumination cassettes, each with 5 fluorescent tubes
* Intuitive touchscreen controller with time-segment and real-time programming with internal data recording
* Door heating
Text of SeriesThe BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this climate chamber to create constant lighting and temperature conditions.

TECHNICAL DATA

DescriptionKBWF720-230V *
  
Article Number9020-0337
Performance Data Temperature 
Temperature range with 100% illumination [°C]10…60
Temperature range without illumination cassettes [°C]0…70
Performance Data Climate 
Temperature range with 100% illumination [°C]20…60
Temperature range without illumination cassettes [°C]10…70
Humidity range with illumination cassettes, with illumination [% RH]10…75
Humidity range without illumination [% RH]10…80
Lightdata per Illumination Cassettes 
Daylight tubes [W/m²]* **38
Daylight tubes [lx]* **13000
Fluora® growth lamps [W/m²]* **36
Fluora® growth lamps [lx]* **10500
Arabidopsis lamps [W/m²]* **43
Arabidopsis lamps [lx]* **14000
Electrical data 
Rated Voltage [V]200…240
Power frequency [Hz]50
Nominal power [kW]3.5
Unit fuse [A]16
Phase (Nominal voltage) [ph]1
Measures – Outer dimensions 
Width net [mm]1250
Height net [mm]1925
Depth net [mm]890
Wall clearance back [mm]100
Wall clearance sidewise [mm]200
Measures – Doors 
Inner doors2
Unit doors2
Measures – Internal Dimensions 
Width [mm]973
Height [mm]1250
Depth [mm]576
Measures 
Interior volume [L]700
Net weight of the unit (empty) [kg]374
permitted load [kg]150
Load per rack [kg]45
Environment-specific data 
Energy consumption at 37 °C and 75 % RH [Wh/h] 
Sound-pressure level [dB(A)]59
Fixtures 
Number of shelves (std./max.)3/12
Number of illumination cassettes (std./max.)3/3

 

 

* All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
** Average value, measured at 25 °C with a spherical sensor (±10 %) by 12 cm below the light cassette. The values given in W/m2 refer to global radiation.

Similar Products

Used Lab Equipment - Thermo Scientific 3110 Series II Water Jacketed CO2 Incubator (Dual Stack) 1

Thermo Scientific 3110 Series II Water Jacketed CO2 Incubator (Dual Stack)

VIEW MORE DETAILS
Used Lab Equipment - Thermo Forma 3110 Series II Water Jacket CO2 Incubator, Dual Stack 3

Thermo Forma 3110 Series II Water Jacket CO2 Incubator, Dual Stack

VIEW MORE DETAILS
Used Lab Equipment - Binder redLINE Incubator Model RI 115-U 5

Binder redLINE Incubator Model RI 115-U

VIEW MORE DETAILS
Used Lab Equipment - New Brunswick Scientific Co Galaxy 170S 7

New Brunswick Scientific Co Galaxy 170S

VIEW MORE DETAILS
Used Lab Equipment - Binder CB210 UL CO2 Incubator 9

Binder CB210 UL CO2 Incubator

VIEW MORE DETAILS
Used Lab Equipment - New Brunswick Scientific Co Innova 4900 Shaking Environmental Chamber 11

New Brunswick Scientific Co Innova 4900 Shaking Environmental Chamber

VIEW MORE DETAILS
Used Lab Equipment - VWR 2375 CO2 Dual Stacked Incubator 13

VWR 2375 CO2 Dual Stacked Incubator

VIEW MORE DETAILS
Used Lab Equipment - SciGene Hybex Microsample Incubation System 15

SciGene Hybex Microsample Incubation System

VIEW MORE DETAILS
Used Lab Equipment - Forma Scientific 3110 Water-Jacketed CO2 Incubator 17

Forma Scientific 3110 Water-Jacketed CO2 Incubator

VIEW MORE DETAILS
Used Lab Equipment - Labnet VorTemp 56 Shaking Incubator 19

Labnet VorTemp 56 Shaking Incubator

VIEW MORE DETAILS