Features of the EG & E Princeton Applied Research Model 362 Scanning Potentiostat include:

– Control E, linear scanning:
                   – Scan range: ±9.999 V to ±9.999 V
                   – Limit resolution: 1 mV steps
                   – Limit accuracy: ±3 mV ±0.4% of initial potential setting.
                   – Scan rate range: 0.1 mV/s to 500 mv/s selected with front panel rotary switch
                   – Scan rate multiplier switch: internal x10 slide switch.
                   – Scan rate resolution: selectable in multiples of 1, 2, and 5
                    – Scan rate accuracy: ±0.0l mV/s ±0.5% scan rate setting
                    – Turn-around accuracy (the point at which the slope of the scan-waveform changes polarity): potential setting ±2 mV ±0.002 x scan rate setting
– Control I, linear scanning:
                      – Applied current range: 100 nA to >1 A
                      – Scan rate range: 1 nA/s to 500 mA/s
                      – Scan rate resolution: selectable in multiples of 1, 2, and 5
                      – Scan rate accuracy: ±1 x 10-5 x current range ±0.5% of scan rate
                      – Scan rate multiplier switch: internal x10 slide switch
                      – Turn-around accuracy: 2 x 103 x current range ±0.02% of scan rate
– Control I, constant I linear scanning:
                       – Applied current range: 100 nA to 1 A
                      – Accuracy: ±0.4% of current range ±0.5% resolution setting
                      – Resolution: 10% to 200% of full-scale current range setting in multiples of 1, 2, and 5 (10% to 100% of 1 a range).
                     – Initial and final thresholds: ±9.999 V to ±9.999 V.
                     – Threshold resolution: 1 mV.
                     – Turn-around accuracy: potential setting ±2 mv ±0.002 x scan rate setting

Similar Products

Used Lab Equipment - PendoTech PMAT2 Benchtop Pressure Sensor Monitor 1

PendoTech PMAT2 Benchtop Pressure Sensor Monitor

VIEW MORE DETAILS
Used Lab Equipment - Veltek Associates, Inc. SMA DDC1 Digital Display Air Sampler Control Center 3

Veltek Associates, Inc. SMA DDC1 Digital Display Air Sampler Control Center

VIEW MORE DETAILS
Used Lab Equipment - SGW X-4 Melting Point Apparatus With Microscope, 220V 5

SGW X-4 Melting Point Apparatus With Microscope, 220V

VIEW MORE DETAILS
Used Lab Equipment - Chemglass Temperature Monitor 7

Chemglass Temperature Monitor

VIEW MORE DETAILS
Used Lab Equipment - Rudolph Research Analytical J-57HA Refractometer with Power Supply 9

Rudolph Research Analytical J-57HA Refractometer with Power Supply

VIEW MORE DETAILS