Features of the Pfeiffer Vacuum HiPace 300 with TC 110 include:
– Bearing: Hybrid
– Compression ratio for Ar: > 1 · 1011
– Compression ratio for H2:9 · 105
– Compression ratio for He:> 1 · 108
– Compression ratio for N2: > 1 · 1011
– Cooling method, optional: Water
– Cooling method, standard: Air
– Cooling water consumption: 50 l/h
– Cooling water temperature: 15-35 °C | 59-95 °F | 288-308 K
– Electronic drive unit: with TC 110
– Flange (in): DN 100 ISO-K
– Flange (out): DN 16 ISO-KF/G ¼”
– Fore-vacuum max. for N2: 15 hPa | 11.25 Torr | 15 mbar
– Gas throughput at full rotational speed for Ar: 2 hPa·l/s
– Gas throughput at full rotational speed for H2: > 14 hPa·l/s
– Gas throughput at full rotational speed for He: 8 hPa·l/s
– Gas throughput at full rotational speed for N2: 5 hPa·l/s
– Interfaces: RS-485, Remote
– Mounting orientation: in any orientation
– Permissible magnetic field max.: 5.5 mT
– Protection category: IP54
– Pumping speed for Ar: 255 l/s
– Pumping speed for H2: 220 l/s
– Pumping speed for He: 255 l/s
– Pumping speed for N2: 260 l/s
– Pumping speed range: 300 l/s
– Rotation speed ± 2 %: 60,000 rpm | 60,000 min-1
– Run-up time: 3.5 min
– Sound pressure level: ≤ 50 dB(A)
– Ultimate pressure according to PNEUROP: < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
– Venting connection: G 1/8″
– Weight: 6.2 kg | 13.67 lb.
– Compression ratio for Ar: > 1 · 1011
– Compression ratio for H2:9 · 105
– Compression ratio for He:> 1 · 108
– Compression ratio for N2: > 1 · 1011
– Cooling method, optional: Water
– Cooling method, standard: Air
– Cooling water consumption: 50 l/h
– Cooling water temperature: 15-35 °C | 59-95 °F | 288-308 K
– Electronic drive unit: with TC 110
– Flange (in): DN 100 ISO-K
– Flange (out): DN 16 ISO-KF/G ¼”
– Fore-vacuum max. for N2: 15 hPa | 11.25 Torr | 15 mbar
– Gas throughput at full rotational speed for Ar: 2 hPa·l/s
– Gas throughput at full rotational speed for H2: > 14 hPa·l/s
– Gas throughput at full rotational speed for He: 8 hPa·l/s
– Gas throughput at full rotational speed for N2: 5 hPa·l/s
– Interfaces: RS-485, Remote
– Mounting orientation: in any orientation
– Permissible magnetic field max.: 5.5 mT
– Protection category: IP54
– Pumping speed for Ar: 255 l/s
– Pumping speed for H2: 220 l/s
– Pumping speed for He: 255 l/s
– Pumping speed for N2: 260 l/s
– Pumping speed range: 300 l/s
– Rotation speed ± 2 %: 60,000 rpm | 60,000 min-1
– Run-up time: 3.5 min
– Sound pressure level: ≤ 50 dB(A)
– Ultimate pressure according to PNEUROP: < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
– Venting connection: G 1/8″
– Weight: 6.2 kg | 13.67 lb.