The Agilent 8890 Gas Chromatograph (GC) With 5977B Inert Plus MSD, G4567A Autoinjector and IDP-3 Dry Scroll Pump provides superior performance for all applications. Key to its performance is the use of advanced electronic pneumatic control (EPC) modules and high-performance GC oven temperature control, which lead to extremely precise retention time reproducibility, the basis for all chromatographic measurement.
The Agilent 8890 Gas Chromatograph (GC) offers a 7-inch capacitive touchscreen interface for real-time access to instrument status, configuration, and flowpath information. A signal plot confirms that analyses are running as intended. Additional tabs provide quick access to key functions such as editing method parameters, diagnostics, maintenance, logs, and help screens.
The Browser Interface is the most extensive interface to the 8890 GC’s intelligence and mobile access features. Optimized for a 10-inch tablet, the Browser Interface can be used on a tablet, PC, or even a phone. Now you can view setup information, troubleshoot problems, check for leaks (autonomous hands-free), backflush columns, pause and start sample runs, and manage method development. GC performance can be monitored by automatically evaluating blanks using advanced onboard analytical techniques. A browser interface optimized for mobile viewing on either iOS or Android phones provides status information including remaining run time and a static plot of the last 20 minutes of detector data.
The Agilent 8890 Gas Chromatograph (GC) has expanded configuration capabilities, where up to two inlets and four detectors can be installed and operated simultaneously. Six GC column Smart Key ports are provided.
Agilent proprietary Capillary Flow Technology provides a new dimension in chromatography with reliable, leak-free, in-oven capillary connections that stand up to repeated GC oven cycling over time. The Agilent 8890 Gas Chromatograph (GC) has enhanced hardware to extend Capillary Flow capabilities, and enhanced data system software to simplify setup and operation of backflush techniques. Programmable eco-friendly Sleep Mode reduces power and gas consumption during periods of inactivity, while Wake Mode readies the system for high-throughput operation.
Agilent 8890 GC Features:
Agilent 8890 GC Specifications: | |
Dimensions | 22.9" W x 20.2" D x 19.2" H (58 x 51 x 49 cm) |
Weight | 108 lbs. (49 kg) |
Column Oven Dimensions | 11.02" W x 6.3" D x 12.2" H (28 × 16 x 31 cm) |
Columns | Accommodates up to two 105 m × 0.530 mm id capillary columns, or two 10-ft glass packed columns (9 in. coil diameter, 1/4 in. od), or two 20-ft stainless steel packed columns (1/8 in. od) |
Operating Temperature Range | Suitable for all columns and chromatographic separations |
Ambient Temperature With LN2 Cryogenic Cooling With CO2 Cryogenic Cooling | –80 to 450 °C –40 to 450 °C +4 to 450 °C |
Temperature Setpoint Resolution | 0.1 °C |
Ramps | Supports 20 oven ramps with 21 plateaus. Negative ramps are allowed. |
Maximum Achievable Temperature Ramp Rate | 120 °C/min (120 V units are limited to 75 °C/min) |
Maximum Run Time | 999.99 minutes (16.7 hours) |
Oven Cool Down (22 °C ambient) | 450 to 50 °C in 4.0 minutes (3.5 minutes with oven insert accessory) |
Ambient Rejection | <0.01 °C per 1 °C |
Supports Simultaneously | Two inlets Four detectors Four detector signals |
Retention Time Repeatability | <0.008 % or <0.0008 minutes |
Area Repeatability | <0.5% RSD |
Specifications: | |
Dimensions | 22.9" W x 20.2" D x 19.2" H (58 x 51 x 49 cm) |
Weight | 108 lbs. (49 kg) |
Column Oven Dimensions | 11.02" W x 6.3" D x 12.2" H (28 × 16 x 31 cm) |
Columns | Accommodates up to two 105 m × 0.530 mm id capillary columns, or two 10-ft glass packed columns (9 in. coil diameter, 1/4 in. od), or two 20-ft stainless steel packed columns (1/8 in. od) |
Operating Temperature Range | Suitable for all columns and chromatographic separations |
Ambient Temperature With LN2 Cryogenic Cooling With CO2 Cryogenic Cooling | –80 to 450 °C –40 to 450 °C +4 to 450 °C |
Temperature Setpoint Resolution | 0.1 °C |
Ramps | Supports 20 oven ramps with 21 plateaus. Negative ramps are allowed. |
Maximum Achievable Temperature Ramp Rate | 120 °C/min (120 V units are limited to 75 °C/min) |
Maximum Run Time | 999.99 minutes (16.7 hours) |
Oven Cool Down (22 °C ambient) | 450 to 50 °C in 4.0 minutes (3.5 minutes with oven insert accessory) |
Ambient Rejection | <0.01 °C per 1 °C |
Supports Simultaneously | Two inlets Four detectors Four detector signals |
Retention Time Repeatability | <0.008 % or <0.0008 minutes |
Area Repeatability | <0.5% RSD |
© Heritage ALT LLC All Rights Reserved